Yamato PPC-300WP Spécifications

Naviguer en ligne ou télécharger Spécifications pour Balance de cuisine Yamato PPC-300WP. Yamato PPC-300WP Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 30
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
YCO-1127-12-08
PPC-300WP Operation Manual
YAMATO CORPORATION
1775 S. Murray Blvd.
Colorado Springs, CO 80916 USA
Tel (719) 591-1500 Fax (719) 591-1045
YAMATO TECH CORPORATION
#112-19425 Langley By-Pass
Surrey, B.C. V3S 6K1 Canada
Tel (604) 533-2338 Fax (604) 533-0827
www.YamatoCorp.com
NTEP CC 08-041
Vue de la page 0
1 2 3 4 5 6 ... 29 30

Résumé du contenu

Page 1 - PPC-300WP Operation Manual

YCO-1127-12-08PPC-300WP Operation ManualYAMATO CORPORATION1775 S. Murray Blvd.Colorado Springs, CO 80916 USATel (719) 591-1500 Fax (719) 591-1045

Page 2

YCO-1127-12-08PPC-300WP Operation Manual Caution Place the scale on its side to access the undercarriage. Do not turn the scale upside down.

Page 3

YCO-1127-12-08PPC-300WP Operation Manual Caution Place the scale on its side to access the undercarriage. Do not turn the scale upside down.

Page 4

YCO-1127-12-08PPC-300WP Operation ManualTurning the Scale On and OffRemove everything from the weighing platform and press the key to turn the scal

Page 5

YCO-1127-12-08PPC-300WP Operation ManualNet Weighing - Tare OperationNet weighing displays the weight of an item without the weight of its container.

Page 6

YCO-1127-12-08PPC-300WP Operation ManualBatch WeighingBatch weighing displays the weight of several different combined items in succession. An examp

Page 7

YCO-1127-12-08PPC-300WP Operation ManualSelectable FunctionsThe PPC-300 family of scales offer three selectable functions to assist you with your wei

Page 8

YCO-1127-12-08PPC-300WP Operation ManualPacking FunctionThe packing function is ideal for lling containers. The numeric display indicates the weigh

Page 9

YCO-1127-12-08PPC-300WP Operation ManualPacking FunctionOnce the packing function is enabled, the target weight and allowable range need to be setup.

Page 10

YCO-1127-12-08PPC-300WP Operation ManualPacking FunctionThis is an example of how the packing function operates once it has been enabled and setup.

Page 11

YCO-1127-12-08PPC-300WP Operation ManualCheckweighing FunctionThe checkweighing function uses a lower limit and upper limit to establish an acceptabl

Page 13

YCO-1127-12-08PPC-300WP Operation ManualCheckweighing FunctionOnce the checkweighing function is enabled, the lower limit and upper limit need to be

Page 14

YCO-1127-12-08PPC-300WP Operation ManualCheckweighing FunctionThis is an example of how the checkweighing function operates once it has been enabled

Page 15

YCO-1127-12-08PPC-300WP Operation ManualGrading FunctionThe grading function allows you to dened up to 15 continuous weight grades and displays the

Page 16

YCO-1127-12-08PPC-300WP Operation ManualGrading FunctionOnce the grading function is enabled, the grade weights need to be setup. Each weight entere

Page 17

YCO-1127-12-08PPC-300WP Operation ManualGrading FunctionThis is an example of how the grading function operates once it has been enabled and setup.

Page 18

YCO-1127-12-08PPC-300WP Operation ManualThe PPC-300 family of scales have nine functional user parameters that can be accessed by pressing the and

Page 19

YCO-1127-12-08PPC-300WP Operation Manual01 - Function SelectionThe PPC-300 series has three user selectable weighing functions: Packing, Checkweighin

Page 20

YCO-1127-12-08PPC-300WP Operation ManualThe scale automatically detects several errors. The following table describes the various errors that can be

Page 21

YCO-1127-12-08PPC-300WP Operation ManualDisplay Condition ActionOverload - there is too much weight on the scale platform.Remove weight from the scal

Page 22

YCO-1127-12-08PPC-300WP Operation Manual

Page 23

YCO-1127-12-08PPC-300WP Operation ManualTable of ContentsI. Introduction 1 Conventions 1 Safety Precautions 1II. Description 4 Name an

Page 24

YCO-1127-12-08YAMATO CORPORATION1775 S. Murray Blvd.Colorado Springs, CO 80916 USATel (719) 591-1500 Fax (719) 591-1045YAMATO TECH CORPORATION#112

Page 25

YCO-1127-12-08PPC-300WP Operation ManualWelcome to your new Yamato scale. This operation manual provides you with instructions on how to setup, use

Page 26

YCO-1127-12-08PPC-300WP Operation Manual Danger - To Avoid Fire and Electric Shock Do not operate the scale if there is smoke or a burnt smell

Page 27

YCO-1127-12-08PPC-300WP Operation Manual To keep the scale working efciently The PPC-300WP is rated IP68 (waterproof) when it has been closed by

Page 28

YCO-1127-12-08PPC-300WP Operation ManualII Description4Name and Function of Parts1) ON/OFF Key Press to turn the power on or to enter function mod

Page 29

YCO-1127-12-08PPC-300WP Operation ManualName and Function of PartsSpecicationsWeighing system: Strain-gauge load cellPlatform: 9.1” x 7.9” (232

Page 30 - YAMATO TECH CORPORATION

YCO-1127-12-08PPC-300WP Operation Manual6II DescriptionSpecicationsDimensions: